Biphasic Defibrillator with AED
ICU,CCU,HDU Solution

Biphasic Defibrillator with AED

M&B DM7000 China Available on Order
  • The DM7000 defibrillator is a compact, multi‑function biphasic device offering AED, manual, monitoring, and pacing modes with selectable 2–360J energy and fast charging for emergency and hospital use.
  • What the DM7000 Is
  • The DM7000 is a clinical defibrillation system designed for Basic Life Support (BLS) and Advanced Cardiac Life Support (ACLS), combining defibrillation, ECG monitoring, AED analysis, and optional SpO₂/NIBP/ETCO₂ modules
Price
Call for Price
Contact us for latest pricing and bulk discounts.
Share:
Product: Defibrillator Monitor
Brand: M & B Electronics Instruments
Model: DM7000
Origin: China

Features:
– High-resolution display 7 inch Screen
– 3/5 Lead ECG Monitoring
– Biphasic waveform
– Manual and Automated Defibrillation
– 2 – 360 Joule energy range
– SpO2 function
– Rechargeable battery providing 3 hours of ECG monitoring or 100 shocks at 360j
– 50mm Thermal Printer
– Easy access user-friendly front panel
– Recessed menu buttons
Display
Screen Type High-resolution display
Screen Size 8 inches diagonally
Sweep Speed 25mm/sec
Information Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.
Defibrillator
Waveform Biphasic
Charge Time Less than 7 seconds with a new fully charged battery.
Energy Display Monitor display indicates both selected and delivered energy.
Charge Prompt Type Voice and visual prompts.
Electrode Impedance Measurement Range 0-250 ohms.
ECG Monitoring
Patient Connection 3-lead ECG cable, or 5-lead ECG cable, paddles.
Lead Selection Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate 20-300BPM.
Heart Rate Alarm On/Off displayed on monitor, user-selectable.
Smart Alarms Beeper/voice prompts indicate shockable rhythm.
Battary
Type Rechargeable, Ni-MH battery, 12V.
Operating Time For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.
SpO2 Module
Measurement Range 30~100%, ±2% between 80%~90%, others ±5%
Alarm Range User set high limit and low limit.
Alarm Accuracy ±10% within setting values.
Alarm time Accuracy less than 12 sec.
Recorder
Paper 50mm thermal.
Speed 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method High-resolution, thermal print head.
Print-out Modes Manual or automatic, user-configurable.
On/Off Control Front panel and paddle.
Automatic Function 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
AED Mode
AED Function Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms Ventricular fibrillation with amplitude >=200uV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
Charge Control Control on device front panel, press key on paddle.
Prompts Voice and visual prompts.
Manual Mode
Energy Selection Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode Synchronizes defibrillator pulse to patient’s R-wave. ”SYNC” message displayed on monitor.